Jaw Crusher Emergency Fault Quick-Reference Table

High-Frequency Operational Issues and Corrective Actions


No.Fault ConditionPrimary CausesCorrective Actions
1Abnormal sharp noise; movable jaw stops while flywheel rotates• Tension spring fatigue or fracture
• Tie rod failure under excessive load
• Non-crushable material causing toggle plate displacement or fracture
• Stop equipment immediately
• Replace damaged tension spring and tie rod
• Secure movable jaw and inspect toggle plate
• Reinstall or replace toggle plate as required
• Perform no-load test before restart
2Material accumulation in crushing chamber with high motor current• Oversized material lodged in chamber
• Discharge conveyor malfunction
• Excessive feed rate or cohesive material
• Stop crusher operation
• Remove blocked material using lifting tools
• Restore downstream conveying system
• Clear discharge opening and reduce feed rate
3Excessive vibration and impact noise from jaw plates• Loose or missing jaw plate bolts
• Failed locking components
• Broken fastening bolts
• Inspect all fastening bolts
• Tighten or replace damaged fasteners
• Replace worn locking springs
• Adjust discharge opening and jaw alignment
4Discharge opening blockage due to adjustment system failure• Adjustment wedge out of operating range
• Non-compliant toggle plate or seat
• Loose adjustment seat bolts
• Structural defects in adjustment seat
• Reset adjustment wedge position
• Replace non-compliant components
• Tighten or replace fastening bolts
• Replace defective adjustment seat
5Movable jaw fracture• Long-term overload operation
• Casting defects in movable jaw
• Ineffective toggle plate protection
• Jaw-frame interference
• Loss of tie rod spring tension
• Discharge opening set below limit
• Uneven material feeding
• Replace movable jaw assembly
• Install compliant toggle plate and seat
• Reassemble eccentric shaft and bearings accurately
• Restore tie rod spring tension
• Adjust discharge opening to specification
• Optimize feed distribution
6Eccentric shaft deformation or fracture• Improper lifting or installation
• Material strength exceeding limits
• Continuous overload operation
• Toggle plate protection failure
• Improper heat treatment
• Replace eccentric shaft
• Standardize lifting and installation process
• Match crusher to material properties
• Use compliant toggle assemblies
• Select shafts with verified heat treatment
7Toggle plate failure• Overload or oversized feed material
• Entry of non-crushable objects
• Misalignment between toggle plate and seat
• Casting defects
• Replace toggle plate
• Control feed size and improve screening
• Replace worn toggle seats
• Ensure parallel and correct installation
8Sudden main unit shutdown; unable to restart• Severe discharge blockage
• V-belt slippage due to low tension or wear
• Loose eccentric shaft locking bushings
• Insufficient or unstable voltage
• Main bearing failure
• Stop feeding and clear blockage completely
• Adjust or replace V-belts
• Reinstall or replace locking bushings and reset clearances
• Stabilize power supply voltage
• Replace damaged bearings and check lubrication